欢迎光临
我们一直在努力

AIX 报错“BFE4C025 P H sysplanar0   UNDETERMINED ERROR”

检查系统时发现系统报错:

$errpt | head

BFE4C025   0529221011 P H sysplanar0     UNDETERMINED ERROR

 

查看对应的错误号,发现如下诊断信息:

$errpt -aj BFE4C025

……

Diagnostic Analysis

Diagnostic Log sequence number: 31453

Resource tested:        sysplanar0

Resource Description:   System Planar

Location:              

SRC=\’#\'” />Description:            Memory subsystem including external cache Predictive

                        Error, general. Refer to the system service

                        documentation for more information.

Additional Words:       2-030000F0 3-28EC0110 4-C13920FF 5-41000000

                        6-00811930 7-00000001 8-00A0008A 9-5600502A

Possible FRUs:

    Priority: M FRU: 00P5773  S/N: YL1081315356 CCIN: 30D5

    Location: U787B.001.DNW7118-P1-C9-C4)

……

 

由于可能是内存问题,查看一下具体的位置:

$lscfg -pv | grep -p DIMM

      Memory DIMM:

        Product Specific.(RT)…….VINI

        Flag Field………………XXMS

        System Info Specific.(YL)…U787B.001.DNW7118-P1-C9-C4

        Customer Card ID Number…..30D5

        Serial Number……………YL1081315356

        Part Number……………..00P5773

        FRU Number……………… 00P5773

        Size……………………2048

        Version…………………RS6K

      Physical Location: U787B.001.DNW7118-P1-C9-C4

 

怀疑是之前仅仅更换了一个2G的内存后,该组内存的配对偶尔会出现问题,查看内存:

$lsattr -El mem0

goodsize  32000 Amount of usable physical memory in Mbytes  False

size      32000 Total amount of physical memory in Mbytes   Fasle

 

更换了一组内存,貌似ok了,等待后续变化。