dell服务器进入安全模式,dell服务器开机提示错误怎么解决

系统:CentOS?6.2?X86_64

内核:2.6.32-220.el6.x86_64

硬件:Dell?PowerEdge?R420

CPU:Intel(R)?Xeon(R)?CPU?E5-2420?0?@?1.90GHz

详细错误信息如下:

WARNING:?at?drivers/pci/intr_remapping.c:715?enable_intr_remapping+0×73/0x2af()?(Not?tainted)

Hardware?name:?PowerEdge?R420

Your?BIOS?has?requested?that?x2apic?be?disabled.

This?will?leave?your?machine?vulnerable?to?irq-injection?attacks.

Use?‘intremap=no_x2apic_optout’?to?override?BIOS?request.

解决:

因ROM默认情况下不使用x2apic

1.忽略

2.使用’intremap=no_x2apic_optout’?内核选项进行启动

如:

#?vim?/boot/grub/grub.conf

title?CentOS?(2.6.32-220.el6.x86_64)

root?(hd0,0)

kernel?/vmlinuz-2.6.32-220.el6.x86_64?ro?root=/dev/mapper/VolGroup00-LogVol00_root?rd_NO_LUKS?rd_LVM_LV=VolGroup00/LogVol01_swap?LANG=en_US.UTF-8?rd_NO_MD?quiet?SYSFONT=latarcyrheb-sun16?rhgb?crashkernel=auto?rd_LVM_LV=VolGroup00/LogVol00_root?KEYBOARDTYPE=pc?KEYTABLE=us?rd_NO_DM?intremap=no_x2apic_optout?#添加该参数,重启服务器解决

initrd?/initramfs-2.6.32-220.el6.x86_64.img